Tolerancing Guide#
Tolerancing answers the question every design has to face before it is built:
will the lens still meet its specification once every radius, thickness,
glass and mounting is slightly off? This guide covers the whole workflow in
optiland.tolerancing. For a worked example from start to finish, see
Tutorial 6d.
A tolerance study has four parts, all held by a
Tolerancing object:
Operands: the performance criteria, such as the RMS spot size or the RMS wavefront error. They are the same operands as in optimization.
Tolerances (or the lower-level perturbations): what may change, and by how much.
Compensators (optional): what is adjusted after assembly, such as the focus.
An analysis:
SensitivityAnalysis,InverseSensitivityorMonteCarlo.
from optiland.samples.objectives import CookeTriplet
from optiland.tolerancing import SensitivityAnalysis, Tolerancing
from optiland.tolerancing.monte_carlo import MonteCarlo
lens = CookeTriplet()
tolerancing = Tolerancing(lens)
# 1. performance criteria
tolerancing.add_operand(
"rms_wavefront",
{"optic": lens, "Hx": 0.0, "Hy": 1.0, "num_rays": 6, "wavelength": 0.55},
target=0.0,
)
# 2. tolerances: deviations from nominal
tolerancing.add_tolerance("radius", 0.1, surface_number=1) # ±0.1 mm
tolerancing.add_tolerance("thickness", minus=-0.02, plus=0.05, surface_number=3)
tolerancing.add_tolerance("element_tilt", 0.03, first=1, last=2, axis="x") # deg
# 3. compensator: refocus by changing the last air gap
tolerancing.add_compensator("thickness", surface_number=6)
# 4. analyses
sensitivity = SensitivityAnalysis(tolerancing)
sensitivity.run()
print(sensitivity.rss_estimate())
monte_carlo = MonteCarlo(tolerancing)
monte_carlo.run(500, seed=1)
print(monte_carlo.yield_fraction({0: ("<=", 0.25)}))
Operands#
Tolerancing.add_operand(operand_type, input_data, target=..., min_val=...,
max_val=...) takes any optimization operand (see
Default Merit and Constraints). The operand values are what the
analyses report, and they are also the merit function of the optimizer
compensators:
With an explicit
target, the compensators drive the operand towards it.target=0.0on an error metric means “minimize”.With no
targetand no bounds, the value at the time the operand is added becomes the target, so the compensators restore the nominal value.With
min_valormax_val, any value inside the range is acceptable and the compensators only act outside it.
Four operands were added with the tolerancing rework, because tolerance specifications are usually stated with them. They are computed by real ray tracing at one field point and wavelength:
Operand |
Value |
|---|---|
|
RMS wavefront error in waves, piston removed. |
|
MTF at one spatial frequency (cycles/mm), |
|
Image position of the chief ray of a field point, as an angle in milliradians: the pointing error of the system. |
All four are in optiland.optimization.operand.image_quality.
Tolerances and perturbations#
There are two ways to state what may change.
Tolerances, added with Tolerancing.add_tolerance, are signed deviations
from the nominal design, between two limits, the way a drawing or an optical
shop states them:
tolerancing.add_tolerance("radius", 0.1, surface_number=1) # [-0.1, +0.1]
tolerancing.add_tolerance("fringes", minus=-1, plus=3, surface_number=2)
tolerancing.add_tolerance("index", 0.0005, surface_number=1, distribution="uniform")
limit gives the symmetric range [-limit, +limit]; minus and
plus give an asymmetric one. The deviation is always added to the nominal
value, so a tolerance does not need to know the design values, and the same
tolerance works on every design. Each call returns the
Tolerance, whose minus, plus and
distribution can be changed later.
Perturbations, added with Tolerancing.add_perturbation(variable_type,
sampler, ...), set absolute values of an optimization variable, in the
variable’s own units (for example a tilt in radians). Their values come from a
sampler: ScalarSampler (one value), RangeSampler (a sweep) or
DistributionSampler (random draws). Perturbations can change any parameter
that has an optimization variable, which makes them the tool for parameters
that no tolerance type covers, and for sweeps. Tutorials
6a and
6b use them.
Both can be used in the same problem. The newer analysis features (the RSS estimate per tolerance limit, inverse sensitivity, seeded and parallel Monte Carlo) are built for tolerances; the notes below say where perturbations are not supported.
Tolerance types#
The registered types, their arguments and units:
Type |
Arguments |
Units |
Deviation |
|---|---|---|---|
|
|
lens units |
Radius of curvature. Not defined on a flat surface; use |
|
|
fringes |
Power: one fringe is half a test wavelength of sag at the edge of the clear aperture, applied as an exact change of radius. A positive value makes the surface more strongly curved. |
|
|
(none) |
Conic constant. |
|
|
lens units |
Thickness after the surface. With |
|
|
Δnd |
d-line index of the material after the surface. The Abbe number and the relative partial dispersions are kept. |
|
|
Δνd |
Abbe number of the material after the surface. The d-line index and the relative partial dispersions are kept. Needs a dispersive material. |
|
|
fringes |
Form error as a Zernike sag error, with a peak-to-valley sag of the
deviation times half the test wavelength. Kind |
|
|
lens units |
Decenter of one surface. |
|
|
degrees |
Tilt of one surface about its vertex. |
|
|
lens units |
Decenter of surfaces |
|
|
degrees |
Tilt of the element about the pivot. |
|
|
degrees |
Rotation of the element about its own axis through the pivot. |
Lens units are those of the optic, usually millimetres. Element types move the
surfaces first to last (inclusive); the surfaces after the element do
not move. pivot is "center" (default, midway between the first and the
last vertex), "first", "last", or a distance from the first vertex
along the element axis. Elements can also be optimized: the variables
"element_decenter", "element_tilt" and "element_roll" take the
same arguments.
The index and Abbe tolerances never modify the glass: they replace the
material with an OffsetMaterial that wraps it, and
restore the original object on reset. The irregularity tolerance likewise wraps
the surface geometry in a SagErrorGeometry.
tolerance_registry.names() lists the registered types. To add a type,
subclass ToleranceType and register it; see
Tolerancing Framework.
Order of application#
In a trial, tolerances are applied in phases, not in the order they were added:
Structure: radius, fringes, conic, thickness.
Material: index, Abbe number.
Form: irregularity.
Rigid body: surface and element decenters, tilts and rolls.
Within a phase, the order of insertion is kept. A thickness change moves every
surface after it, so rigid-body moves come last and are applied to the
surfaces where they already are; reset runs in the reverse order and restores
the nominal design exactly. Tolerancing.ordered_perturbations() returns the
order used. Perturbations added with add_perturbation belong to the
structure phase.
Distributions#
Monte Carlo analyses draw each deviation from the tolerance’s distribution,
set with distribution=:
Name |
Distribution |
|---|---|
|
Normal distribution truncated at the limits, centred between them, with
the limits at ±2σ. Use
|
|
Uniform between the limits. |
|
Density proportional to the squared distance from the centre: values near the limits are the most likely. |
|
One of the two limits, with equal probability. |
A Distribution instance can be passed
instead of a name. Sampling always uses NumPy’s random generator, so seeded
results are the same on both backends. Sensitivity and inverse sensitivity
analyses do not sample: they use the limits.
Compensators#
A compensator models an adjustment made after assembly. Optiland has two kinds.
Optimizer compensators: add_compensator(variable_type, **kwargs) adds an
optimization variable, such as "thickness" (refocus), "decenter" or
"tilt". On every trial, the compensator optimizer adjusts the variables to
minimize the operands (see Operands above). It runs through
optiland.optimization.minimize(); Tolerancing(optic, method=...,
tol=...) chooses L-BFGS-B ("generic", default) or Levenberg–Marquardt
("least_squares"). A trial that cannot be traced is left uncompensated
instead of stopping the analysis. The compensated values are reported in the
result tables, in columns named "C0: ...", "C1: ...".
Quick focus: add_compensator("quick_focus", Hx=0, Hy=0, wavelength="primary",
num_rays=5, distribution="hexapolar") moves the image surface along z with
the closed-form QuickFocusSolve instead of an
optimizer, which is much faster. It runs before the optimizer compensators, and
adding it again replaces it. Its result column is "quick_focus: image
distance", the distance from the last surface to the image.
Caution
QuickFocusSolve places the image at the mean of the axial positions
where each traced ray comes closest to the optical axis. This is close to,
but not exactly, the minimum RMS spot position, and it is measured from the
optical axis. It is meant for coaxial systems: when decenters or tilts move
the image off the axis, use an optimizer compensator, such as the
thickness of the last air gap.
Analyses#
Sensitivity analysis#
SensitivityAnalysis applies each
tolerance alone, at its lower and at its upper limit (a perturbation over every
value of its RangeSampler), applies the compensators and evaluates the
operands. get_results() returns one row per trial. After the trials, the
operands are evaluated once more at nominal, with compensators, which is the
reference for the summaries:
rss_estimate()takes, for each tolerance, the larger change of each operand at its two limits, and combines the changes by root sum of squares (RSS). It returns the compensatednominal, therss_changeand theestimate(their sum) per operand. RSS assumes small, independent changes; use Monte Carlo to check it.view_tornado(operand_index=0, top=None)plots the change at each end of every tolerance, sorted with the largest on top.view()plots each operand against each perturbation value.
A sensitivity analysis takes at most six operands and six perturbations or tolerances, a limit of its plot grid. For a full tolerance set, split it over several runs, or use inverse sensitivity or Monte Carlo, which have no limit.
Inverse sensitivity#
InverseSensitivity turns the question
around: given an allowed change of some operands, how large may each tolerance
be? max_change maps an operand index to the allowed absolute change from
the compensated nominal value:
from optiland.tolerancing import InverseSensitivity
inverse = InverseSensitivity(tolerancing, max_change={0: 0.05})
inverse.run()
inverse.get_results() # inverse_minus, inverse_plus, limiting_*, capped_*
inverse.apply_limits() # optional: write the limits into the tolerances
Each side of each tolerance is searched on its own: the deviation is applied
alone and compensated, and the search finds the largest deviation that keeps
every listed operand within its change (bracketing from the current limit,
then Brent’s method). A side that still meets the budget at max_factor
(default 100) times the current limit is reported as capped. Only
tolerances are searched; perturbations stay at nominal.
Monte Carlo#
MonteCarlo applies all tolerances at once,
each drawn from its distribution, compensates and evaluates, for
num_iterations trials:
monte_carlo = MonteCarlo(tolerancing)
monte_carlo.run(1000, seed=42)
monte_carlo.percentiles() # 50, 90 and 98 % by default
monte_carlo.yield_fraction({0: ("<=", 0.25), # operand index ...
"C0: Thickness, Surface 6": (">", 41.5)}) # ... or column
monte_carlo.view_histogram()
monte_carlo.view_cdf()
monte_carlo.view_heatmap()
seedmakes a run reproducible: each trial draws from its own generator, spawned fromnumpy.random.SeedSequence(seed). Perturbations keep their own samplers and are not seeded.yield_fraction(spec)returns the fraction of trials that meet every condition. A trial with a NaN value (one that could not be traced) fails.percentiles(q)gives the operand and compensator values per percentile, leaving out NaN trials.workers=nsplits the trials overnprocesses. The results equal a serial run with the same seed. It needs the NumPy backend and tolerances only (noadd_perturbation), and on Windows and macOS the call must sit underif __name__ == "__main__":, as for any Python multiprocessing.
Tolerance tables#
Tolerancing.add_default_tolerances(table, surfaces=None) applies a table of
tolerances to every matching part of the design, the way a shop’s standard
tolerances apply to every lens:
shop_table = {
"radius": 0.05,
"fringes": 2,
"irregularity": 0.5,
"thickness": 0.05,
"surface_tilt": 0.017, # 1 arc minute
"element_decenter": 0.02,
"index": {"limit": 0.0005, "distribution": "uniform"},
"abbe": 0.5,
}
added = tolerancing.add_default_tolerances(shop_table)
An entry is a number (a symmetric limit) or a dictionary of limit, or
minus and plus, and optionally distribution. Types are placed as
follows:
surface types (radius, fringes, conic, irregularity, surface decenter and tilt): every refracting or reflecting surface; radius and conic only on curved ones;
"thickness": every gap next to such a surface, except the gap before the image, which is usually the focus compensator;element types: every run of surfaces with glass between them;
"index"and"abbe": every surface followed by glass;decenters and tilts once about x and once about y.
surfaces= restricts the table to some surface numbers (an element is kept
when its first surface is listed). Types without a default placement, such as
"element_roll", are added with add_tolerance.
Optiland ships no grade tables. The “commercial”, “precision” and “high precision” values found in textbooks and vendor catalogs differ from vendor to vendor and change with the part size and the process, and no standard defines them: ISO 10110 defines how a tolerance is written on a drawing, not its value. Built-in values would look authoritative without being so. Use the table your shop or vendor quotes, and keep it with your project.
ISO 10110 drawings#
optiland.tolerancing.iso10110_bridge connects tolerancing with the ISO
10110 drawing specification of optiland.iso10110
(Tutorial 11a):
Tolerancing.add_tolerances_from_drawing(drawing)(ortolerances_from_drawing(tolerancing, drawing)) adds the tolerances stated by aDrawingSpec.drawing_values_from_tolerancing(tolerancing)reports the drawing fields implied by the tolerances, as keyword arguments forDrawingSpec.set_surface(under"surfaces") andDrawingSpec.set_element(under"elements").
Drawing field |
Tolerance |
|---|---|
|
|
|
|
|
|
|
|
ISO 10110 has no field for an index or Abbe-number offset (the homogeneity
classes are not offsets), so these, air-space thicknesses and element
decenters, tilts and rolls are not read from or written to drawings. A field
that cannot be mapped is skipped with a UserWarning, or raises with
strict=True.
See also#