Tolerancing Guide#

Tolerancing answers the question every design has to face before it is built: will the lens still meet its specification once every radius, thickness, glass and mounting is slightly off? This guide covers the whole workflow in optiland.tolerancing. For a worked example from start to finish, see Tutorial 6d.

A tolerance study has four parts, all held by a Tolerancing object:

  1. Operands: the performance criteria, such as the RMS spot size or the RMS wavefront error. They are the same operands as in optimization.

  2. Tolerances (or the lower-level perturbations): what may change, and by how much.

  3. Compensators (optional): what is adjusted after assembly, such as the focus.

  4. An analysis: SensitivityAnalysis, InverseSensitivity or MonteCarlo.

from optiland.samples.objectives import CookeTriplet
from optiland.tolerancing import SensitivityAnalysis, Tolerancing
from optiland.tolerancing.monte_carlo import MonteCarlo

lens = CookeTriplet()
tolerancing = Tolerancing(lens)

# 1. performance criteria
tolerancing.add_operand(
    "rms_wavefront",
    {"optic": lens, "Hx": 0.0, "Hy": 1.0, "num_rays": 6, "wavelength": 0.55},
    target=0.0,
)

# 2. tolerances: deviations from nominal
tolerancing.add_tolerance("radius", 0.1, surface_number=1)           # ±0.1 mm
tolerancing.add_tolerance("thickness", minus=-0.02, plus=0.05, surface_number=3)
tolerancing.add_tolerance("element_tilt", 0.03, first=1, last=2, axis="x")  # deg

# 3. compensator: refocus by changing the last air gap
tolerancing.add_compensator("thickness", surface_number=6)

# 4. analyses
sensitivity = SensitivityAnalysis(tolerancing)
sensitivity.run()
print(sensitivity.rss_estimate())

monte_carlo = MonteCarlo(tolerancing)
monte_carlo.run(500, seed=1)
print(monte_carlo.yield_fraction({0: ("<=", 0.25)}))

Operands#

Tolerancing.add_operand(operand_type, input_data, target=..., min_val=..., max_val=...) takes any optimization operand (see Default Merit and Constraints). The operand values are what the analyses report, and they are also the merit function of the optimizer compensators:

  • With an explicit target, the compensators drive the operand towards it. target=0.0 on an error metric means “minimize”.

  • With no target and no bounds, the value at the time the operand is added becomes the target, so the compensators restore the nominal value.

  • With min_val or max_val, any value inside the range is acceptable and the compensators only act outside it.

Four operands were added with the tolerancing rework, because tolerance specifications are usually stated with them. They are computed by real ray tracing at one field point and wavelength:

Operand

Value

"rms_wavefront"

RMS wavefront error in waves, piston removed. remove_tilt=True also removes tilt (RMS referenced to the centroid).

"mtf"

MTF at one spatial frequency (cycles/mm), azimuth="tangential" or "sagittal".

"boresight_x", "boresight_y"

Image position of the chief ray of a field point, as an angle in milliradians: the pointing error of the system.

All four are in optiland.optimization.operand.image_quality.

Tolerances and perturbations#

There are two ways to state what may change.

Tolerances, added with Tolerancing.add_tolerance, are signed deviations from the nominal design, between two limits, the way a drawing or an optical shop states them:

tolerancing.add_tolerance("radius", 0.1, surface_number=1)          # [-0.1, +0.1]
tolerancing.add_tolerance("fringes", minus=-1, plus=3, surface_number=2)
tolerancing.add_tolerance("index", 0.0005, surface_number=1, distribution="uniform")

limit gives the symmetric range [-limit, +limit]; minus and plus give an asymmetric one. The deviation is always added to the nominal value, so a tolerance does not need to know the design values, and the same tolerance works on every design. Each call returns the Tolerance, whose minus, plus and distribution can be changed later.

Perturbations, added with Tolerancing.add_perturbation(variable_type, sampler, ...), set absolute values of an optimization variable, in the variable’s own units (for example a tilt in radians). Their values come from a sampler: ScalarSampler (one value), RangeSampler (a sweep) or DistributionSampler (random draws). Perturbations can change any parameter that has an optimization variable, which makes them the tool for parameters that no tolerance type covers, and for sweeps. Tutorials 6a and 6b use them.

Both can be used in the same problem. The newer analysis features (the RSS estimate per tolerance limit, inverse sensitivity, seeded and parallel Monte Carlo) are built for tolerances; the notes below say where perturbations are not supported.

Tolerance types#

The registered types, their arguments and units:

Type

Arguments

Units

Deviation

"radius"

surface_number

lens units

Radius of curvature. Not defined on a flat surface; use "fringes".

"fringes"

surface_number, test_wavelength (µm, default 0.6328), semi_aperture

fringes

Power: one fringe is half a test wavelength of sag at the edge of the clear aperture, applied as an exact change of radius. A positive value makes the surface more strongly curved.

"conic"

surface_number

(none)

Conic constant.

"thickness"

surface_number, adjust

lens units

Thickness after the surface. With adjust, the thickness after that surface changes by the opposite amount, so later surfaces stay in place.

"index"

surface_number

Δnd

d-line index of the material after the surface. The Abbe number and the relative partial dispersions are kept.

"abbe"

surface_number

Δνd

Abbe number of the material after the surface. The d-line index and the relative partial dispersions are kept. Needs a dispersive material.

"irregularity"

surface_number, kind ("B" or "C"), angle (degrees, kind B), test_wavelength, semi_aperture

fringes

Form error as a Zernike sag error, with a peak-to-valley sag of the deviation times half the test wavelength. Kind "B" (default) is astigmatism, kind "C" rotationally symmetric (spherical, power removed), as in the ISO 10110-5 code 3/A(B/C).

"surface_decenter"

surface_number, axis ("x" or "y")

lens units

Decenter of one surface.

"surface_tilt"

surface_number, axis ("x" or "y")

degrees

Tilt of one surface about its vertex.

"element_decenter"

first, last, axis ("x" or "y")

lens units

Decenter of surfaces first to last as one rigid body.

"element_tilt"

first, last, axis ("x" or "y"), pivot

degrees

Tilt of the element about the pivot.

"element_roll"

first, last, pivot

degrees

Rotation of the element about its own axis through the pivot.

Lens units are those of the optic, usually millimetres. Element types move the surfaces first to last (inclusive); the surfaces after the element do not move. pivot is "center" (default, midway between the first and the last vertex), "first", "last", or a distance from the first vertex along the element axis. Elements can also be optimized: the variables "element_decenter", "element_tilt" and "element_roll" take the same arguments.

The index and Abbe tolerances never modify the glass: they replace the material with an OffsetMaterial that wraps it, and restore the original object on reset. The irregularity tolerance likewise wraps the surface geometry in a SagErrorGeometry.

tolerance_registry.names() lists the registered types. To add a type, subclass ToleranceType and register it; see Tolerancing Framework.

Order of application#

In a trial, tolerances are applied in phases, not in the order they were added:

  1. Structure: radius, fringes, conic, thickness.

  2. Material: index, Abbe number.

  3. Form: irregularity.

  4. Rigid body: surface and element decenters, tilts and rolls.

Within a phase, the order of insertion is kept. A thickness change moves every surface after it, so rigid-body moves come last and are applied to the surfaces where they already are; reset runs in the reverse order and restores the nominal design exactly. Tolerancing.ordered_perturbations() returns the order used. Perturbations added with add_perturbation belong to the structure phase.

Distributions#

Monte Carlo analyses draw each deviation from the tolerance’s distribution, set with distribution=:

Name

Distribution

"normal" (default)

Normal distribution truncated at the limits, centred between them, with the limits at ±2σ. Use TruncatedNormal with num_sigma for another width.

"uniform"

Uniform between the limits.

"parabolic"

Density proportional to the squared distance from the centre: values near the limits are the most likely.

"end_point"

One of the two limits, with equal probability.

A Distribution instance can be passed instead of a name. Sampling always uses NumPy’s random generator, so seeded results are the same on both backends. Sensitivity and inverse sensitivity analyses do not sample: they use the limits.

Compensators#

A compensator models an adjustment made after assembly. Optiland has two kinds.

Optimizer compensators: add_compensator(variable_type, **kwargs) adds an optimization variable, such as "thickness" (refocus), "decenter" or "tilt". On every trial, the compensator optimizer adjusts the variables to minimize the operands (see Operands above). It runs through optiland.optimization.minimize(); Tolerancing(optic, method=..., tol=...) chooses L-BFGS-B ("generic", default) or Levenberg–Marquardt ("least_squares"). A trial that cannot be traced is left uncompensated instead of stopping the analysis. The compensated values are reported in the result tables, in columns named "C0: ...", "C1: ...".

Quick focus: add_compensator("quick_focus", Hx=0, Hy=0, wavelength="primary", num_rays=5, distribution="hexapolar") moves the image surface along z with the closed-form QuickFocusSolve instead of an optimizer, which is much faster. It runs before the optimizer compensators, and adding it again replaces it. Its result column is "quick_focus: image distance", the distance from the last surface to the image.

Caution

QuickFocusSolve places the image at the mean of the axial positions where each traced ray comes closest to the optical axis. This is close to, but not exactly, the minimum RMS spot position, and it is measured from the optical axis. It is meant for coaxial systems: when decenters or tilts move the image off the axis, use an optimizer compensator, such as the thickness of the last air gap.

Analyses#

Sensitivity analysis#

SensitivityAnalysis applies each tolerance alone, at its lower and at its upper limit (a perturbation over every value of its RangeSampler), applies the compensators and evaluates the operands. get_results() returns one row per trial. After the trials, the operands are evaluated once more at nominal, with compensators, which is the reference for the summaries:

  • rss_estimate() takes, for each tolerance, the larger change of each operand at its two limits, and combines the changes by root sum of squares (RSS). It returns the compensated nominal, the rss_change and the estimate (their sum) per operand. RSS assumes small, independent changes; use Monte Carlo to check it.

  • view_tornado(operand_index=0, top=None) plots the change at each end of every tolerance, sorted with the largest on top.

  • view() plots each operand against each perturbation value.

A sensitivity analysis takes at most six operands and six perturbations or tolerances, a limit of its plot grid. For a full tolerance set, split it over several runs, or use inverse sensitivity or Monte Carlo, which have no limit.

Inverse sensitivity#

InverseSensitivity turns the question around: given an allowed change of some operands, how large may each tolerance be? max_change maps an operand index to the allowed absolute change from the compensated nominal value:

from optiland.tolerancing import InverseSensitivity

inverse = InverseSensitivity(tolerancing, max_change={0: 0.05})
inverse.run()
inverse.get_results()   # inverse_minus, inverse_plus, limiting_*, capped_*
inverse.apply_limits()  # optional: write the limits into the tolerances

Each side of each tolerance is searched on its own: the deviation is applied alone and compensated, and the search finds the largest deviation that keeps every listed operand within its change (bracketing from the current limit, then Brent’s method). A side that still meets the budget at max_factor (default 100) times the current limit is reported as capped. Only tolerances are searched; perturbations stay at nominal.

Monte Carlo#

MonteCarlo applies all tolerances at once, each drawn from its distribution, compensates and evaluates, for num_iterations trials:

monte_carlo = MonteCarlo(tolerancing)
monte_carlo.run(1000, seed=42)

monte_carlo.percentiles()                       # 50, 90 and 98 % by default
monte_carlo.yield_fraction({0: ("<=", 0.25),    # operand index ...
                            "C0: Thickness, Surface 6": (">", 41.5)})  # ... or column
monte_carlo.view_histogram()
monte_carlo.view_cdf()
monte_carlo.view_heatmap()
  • seed makes a run reproducible: each trial draws from its own generator, spawned from numpy.random.SeedSequence(seed). Perturbations keep their own samplers and are not seeded.

  • yield_fraction(spec) returns the fraction of trials that meet every condition. A trial with a NaN value (one that could not be traced) fails.

  • percentiles(q) gives the operand and compensator values per percentile, leaving out NaN trials.

  • workers=n splits the trials over n processes. The results equal a serial run with the same seed. It needs the NumPy backend and tolerances only (no add_perturbation), and on Windows and macOS the call must sit under if __name__ == "__main__":, as for any Python multiprocessing.

Tolerance tables#

Tolerancing.add_default_tolerances(table, surfaces=None) applies a table of tolerances to every matching part of the design, the way a shop’s standard tolerances apply to every lens:

shop_table = {
    "radius": 0.05,
    "fringes": 2,
    "irregularity": 0.5,
    "thickness": 0.05,
    "surface_tilt": 0.017,                      # 1 arc minute
    "element_decenter": 0.02,
    "index": {"limit": 0.0005, "distribution": "uniform"},
    "abbe": 0.5,
}
added = tolerancing.add_default_tolerances(shop_table)

An entry is a number (a symmetric limit) or a dictionary of limit, or minus and plus, and optionally distribution. Types are placed as follows:

  • surface types (radius, fringes, conic, irregularity, surface decenter and tilt): every refracting or reflecting surface; radius and conic only on curved ones;

  • "thickness": every gap next to such a surface, except the gap before the image, which is usually the focus compensator;

  • element types: every run of surfaces with glass between them;

  • "index" and "abbe": every surface followed by glass;

  • decenters and tilts once about x and once about y.

surfaces= restricts the table to some surface numbers (an element is kept when its first surface is listed). Types without a default placement, such as "element_roll", are added with add_tolerance.

Optiland ships no grade tables. The “commercial”, “precision” and “high precision” values found in textbooks and vendor catalogs differ from vendor to vendor and change with the part size and the process, and no standard defines them: ISO 10110 defines how a tolerance is written on a drawing, not its value. Built-in values would look authoritative without being so. Use the table your shop or vendor quotes, and keep it with your project.

ISO 10110 drawings#

optiland.tolerancing.iso10110_bridge connects tolerancing with the ISO 10110 drawing specification of optiland.iso10110 (Tutorial 11a):

  • Tolerancing.add_tolerances_from_drawing(drawing) (or tolerances_from_drawing(tolerancing, drawing)) adds the tolerances stated by a DrawingSpec.

  • drawing_values_from_tolerancing(tolerancing) reports the drawing fields implied by the tolerances, as keyword arguments for DrawingSpec.set_surface (under "surfaces") and DrawingSpec.set_element (under "elements").

Drawing field

Tolerance

r_tolerance (±a, a or +a/-b, mm)

"radius". Flat surfaces are skipped.

3/A(B/C): sag_tolerance (A), irregularity (B), rotationally_symmetric (C)

"fringes", "irregularity" kind B, "irregularity" kind C, at the drawing’s test_wavelength (546.07 nm when unset). With form_unit="nm" the values are converted to fringes.

4/σ'(δ): centration σ (arc minutes), centration_decentration δ (mm)

"surface_tilt" about x and y, in degrees, and "surface_decenter" in x and y. centering="per_axis" (default) gives each axis ±σ; centering="rss" gives ±σ/√2, so the combined tilt is σ.

ct_tolerance of a singlet (mm)

"thickness" after its first surface. With adjust_thickness=True (default) the following air space absorbs the change. Cemented elements are skipped.

ISO 10110 has no field for an index or Abbe-number offset (the homogeneity classes are not offsets), so these, air-space thicknesses and element decenters, tilts and rolls are not read from or written to drawings. A field that cannot be mapped is skipped with a UserWarning, or raises with strict=True.