Ray Tracing Framework#

The ray tracing framework in Optiland simulates light propagation through an optical system. It handles various types of rays, supports flexible ray generation, and traces rays across surfaces in sequential optical systems.

Ray Representation#

Rays are the fundamental elements of the ray tracing process. A ray consists of the following attributes:

  • Origin (x, y, z): The starting point of the ray.

  • Direction (L, M, N): The ray’s unit vector indicating its direction.

  • Wavelength: The wavelength of the ray in the system.

  • Intensity: The ray’s relative intensity.

  • Optical Path Difference (OPD): The accumulated path difference of the ray relative to the chief ray.

  • Polarization Matrix (optional): A 3x3 matrix representing the transformation of a ray’s initial electric field into its final state. This is used by the PolarizedRays class.

Note

Ray attributes use arrays from the active backend (NumPy or optional Torch).

Ray Types#

Optiland supports three types of rays:

  • Real Rays: Standard rays with full 3D attributes, used for detailed tracing.

  • Paraxial Rays: Simplified rays using only height (y), angle (u), wavelength, and starting position (z). These are used for first-order system analysis.

  • Polarized Rays: Rays with additional polarization information, allowing simulations involving birefringent materials or coatings.

Ray Generation#

The ray tracing framework uses a Ray Generator to produce rays for tracing. The generator operates based on user-defined parameters, including:

  • Field points

  • Wavelengths

  • Aperture sampling (e.g., uniform grid, random, etc.)

  • Polarization state

  • System properties (e.g., F/#, NA, telecentricity)

  • Apodization (intensity distribution within the pupil)

Generated rays are passed to the Surface Group for tracing through the optical system. Each Optic instance has a ray_tracer attribute, which in turn contains the RayGenerator.

Ray Tracing#

For real rays, the ray tracing process is managed by the RealRayTracer. The ray tracer is responsible for:

  • Generating the appropriate rays via its RayGenerator.

  • Ray tracing input validation.

  • Propagating rays through the surface group.

For paraxial rays, there are two primary methods for tracing: - The ParaxialRayTracer class provides a dedicated tracer for paraxial rays. - The Surface.trace method can also directly handle ParaxialRays, providing an alternative way to trace them.

Tracing Process#

Ray tracing is performed by sequentially propagating rays across the surfaces in the system:

  1. Rays are converted into the local coordinate system of the current surface.

  2. Rays intersections with the surface are identified and the ray propagates to the intersection point.

  3. If the surface has a physical aperture, rays may be clipped (intensity set to zero) if they fall outside this aperture.

  4. The rays interact with the surface, modifying their direction, intensity, polarization matrix, and other attributes.

  5. Ray are transformed back to the global coordinate system.

  6. Ray information (intersection points, intensities, etc.) is recorded on the surface for later analysis and visualization.

  7. The process is repeated for each surface in the system.

Paraxial rays follow a similar process but use simplified equations for faster computations.

Polarization frames and scalar power#

PolarizedRays.p maps the fixed incident electric-field basis to the current output frame. Coordinate-system localization/globalization rotates its output rows alongside ray positions and directions; it retains the original input basis. This permits a local Cartesian Jones element on a tilted surface without interpreting its coefficients as incidence-plane s/p coefficients.

Use rays.attenuate(factor) for polarization-independent intensity losses, and rays.clip(mask) to extinguish rays. In polarized bundles these operations update the retained scalar power as well as the currently evaluated intensity. update_intensity(state) can then evaluate another incident state without restoring absorbed/clipped power or applying a previous loss twice. get_exit_fields(state) includes the corresponding square-root field scaling. Unpolarized light uses two orthogonal incoherent fields whose powers add to the reported intensity.

A zero intensity for one incident polarization is not the same as a clipped ray: a polarizer that blocks vertical input may still transmit horizontal input. Retained scalar power distinguishes these cases. Extinguished rays remain dark even if a later missed surface produces invalid geometry or polarization matrices. Invalid results on rays with nonzero retained power remain visible; they are not silently converted to zero.

Responsibilities and callers#

Component

Responsibility and callers

RealRays.attenuate / PolarizedRays.attenuate

Apply scalar intensity factors. Called by SimpleCoating, HomogeneousPropagation and phase-profile efficiency handling.

PolarizedRays.clip

Extinguish both current intensity and retained scalar power. Called by physical-aperture clipping and other ray rejection paths.

PolarizedRays.rotate_x/y/z

Transport output fields with the ray frame. Called by coordinate-system transforms; supports scalar or per-ray rotation angles in radians.

CartesianJonesCoating

Apply local X/Y complex coefficients after geometrical interaction. Called by surface coating dispatch; available to file readers.

update_intensity / get_exit_fields

Evaluate an incident state using retained transport and scalar power. Used by the real-ray tracer and field/polarization analyses.

PolarizationState / OpticSerializer

Own source-state validation and backend-independent native JSON. File readers reuse that existing contract rather than adding another polarization representation.

Directly assigning rays.i changes only the current evaluation. Custom scalar loss models should call attenuate so subsequent field/state evaluation keeps their losses. This does not change Jones matrices into intensity coefficients.

Interaction update order#

A surface interaction records the normalized incoming direction in L0/M0/N0, assigns and normalizes the outgoing L/M/N, then applies scattering and the coating. The coating transports the field through that bend; without a coating, the interaction calls rays.update() itself. Each bend must update the field exactly once. _L0/_M0/_N0 retain the original launch direction and must not be overwritten with a subsequent surface’s direction.

ThinLensInteractionModel follows this same sequence. It refreshes the incident direction at every lens, so a first polarized thin lens and chained lenses work without missing or stale incident-direction data. The outgoing direction is established before scalar or Jones coating evaluation. Scattering acts on that outgoing direction and is no longer overwritten by the lens. An infinite focal length is a zero-power lens: it contributes no lens phase and preserves the incoming optical path, including for a reflective surface.

Changes to existing results#

Coordinate transformations now rotate the output field with ray positions and directions. The incident field basis remains fixed. Consequently a native PolarizerCoating with local X transmission and a surface Z rotation of 45 degrees transmits horizontal input with field (0.5, 0.5, 0) and power 0.5 for unit incident power. Previously the unrotated field matrix incorrectly gave (1, 0, 0) and power 1. Coating axes are expressed in the surface’s local frame; a direct Jones calculation uses the frame of its supplied rays.

SimpleCoating now transports the field through the geometrical bend before applying its scalar power factor, just as an uncoated surface transports it. Previously that field could cease to be transverse after refraction/reflection. For example, a unit horizontal ray incident at 0.35 radians onto a 1-to-1.5 interface with transmittance 0.36 leaves with amplitude 0.6 * (cos(beta), 0, -sin(beta)), where beta = asin(sin(0.35) / 1.5). Its evaluated power remains 0.36 rather than returning to 1.

Simple-coating losses, bulk absorption, phase efficiency and clipping now persist through source-state re-evaluation and exit-field analyses. The private _i0 therefore stores incident power multiplied by accumulated scalar intensity factors, rather than immutable launch power. Jones amplitude losses remain in p. Zero power stays zero after a later invalid intersection; invalid fields on powered rays are still exposed. Blocking one incident polarization in p does not prevent evaluating another transmitted state.

Scalar ray geometry and optical path calculations are unchanged. Aligned, lossless polarized systems retain their previous results. Tilted anisotropic elements, scalar-coated bends and polarized power/field analyses with scalar loss or clipping may change for the corrections above.

Note

For details on how rays interact with surfaces, see the Surface Overview section.

Extensibility#

The framework is designed to be extensible:

  • New ray types can be added by subclassing the BaseRays base class.

  • Custom ray generators can be implemented by following the existing interface.

  • Additional tracing logic can be integrated into the surface trace method for specialized applications.

For a practical example of ray tracing, see the Getting Starting with the Codebase section.

Ray Aiming#

Optiland implements a flexible Ray Aiming system to determine the correct launch coordinates for rays such that they fill the stop surface, even in systems with significant pupil aberrations.

This functionality is managed by the BaseRayAimer class and its subclasses. The system uses a Registry Pattern, allowing users to easily switch strategies or register custom ones.

Available Strategies#

  • Paraxial: Standard aiming using paraxial entrance pupil approximation. Fast but less accurate for wide-angle/aberrated systems.

  • Iterative: Uses a Newton-Raphson-like iterative solver to refine ray launch coordinates until they hit the physical stop.

  • Robust: An extension of the iterative method using Chief-Ray Calibration (or Pupil Map). It determines the entrance-pupil center per field first (via field-marching continuation), fits a local 2D affine pupil map from cardinal edge probes, and uses this map to seed a fast and precise 2-DOF Newton-Broyden polish step. This guarantees convergence in highly stressed and wide-angle systems.

  • Cached: A wrapper that caches intermediate results from any other strategy. Retained for backward compatibility (explicit cache=True), but retired-by-default for the robust aimer, which implements its own intrinsic, always-on warm-start PupilMapCache.

Configuration#

Ray aiming is configured via the ray tracer on the Optic instance:

# Enable robust ray aiming
optic.ray_tracer.set_aiming(mode="robust", max_iter=20, tol=1e-6)

Custom Aimers#

Users can implement custom strategies by subclassing BaseRayAimer and registering them:

from optiland.rays.ray_aiming import BaseRayAimer, register_aimer

@register_aimer("my_custom_aimer")
class MyAimer(BaseRayAimer):
    def aim_rays(self, fields, wavelengths, pupil_coords):
        # Custom logic
        return x, y, z, L, M, N